Chapter Four Configuration
Man_805U Rev 1.9 Page 41
View Configuration
The AT&V command will output to the terminal a listing of all configuration settings.
AT&V
Show all settings including S registers
&V0
Same as AT&V
&V1
Only show settings that are
different from the defaults.
Transmit and Receive Hold-off times
Transmit holdoff ATS16=x where x is the delay time in msec (0 – 255)
For example, ATS16=200 results in a transmit holdoff delay of 200msec.
Receive holdoff ATS15=x where x is the delay time in msec (0 – 255)
For example, ATS15=80 results in a receive holdoff delay of 80msec.